### Problem

```
com.inductiveautomation.ignition.client.gateway_interface.GatewayException: com.inductiveautomation.ignition.client.gateway_interface.GatewayException: 
Attempt to read the MES object manager before it has been assigned.
 caused by GatewayException: Attempt to read the MES object manager before it has been assigned.
 caused by Error: Attempt to read the MES object manager before it has been assigned.
```

### Solution

That exception happens when the Manager is not started. Things that can cause that:

1) calling too early

2) if the module is in trial on startup we do not start some managers

3) an exception happened in initializing and the manager did not start =&gt; check the logs

If you have Gateway startup or timer scripts calling mes functions, try introducing logic to determine if the production module has been started:

[system.mes.isProductionStarted](/smart/project-imported-manual/system-mes-isproductionstarted)

```python
if system.mes.isProductionStarted():
	#call your scripts
	pass
```