title: "Database Clustering and Primary Key Retrofit"
id: "database-clustering-and-primary-key-retrofit"
project: "Knowledge Base"
url: "https://docs.sepasoft.com/articles/knowledge-base/database-clustering-and-primary-key-retrofit"
updated: 2026-10-13T15:47:36Z
---

# Database Clustering and Primary Key Retrofit

## Knowledge Base Article: MES Database Clustering and Primary Key Retrofit

| ![Note](/resources/Storage/knowledge-base/Note.png) | **Version Specific:**<br><br>Use these steps when adding primary keys to versions **before 3.81.12 SP0**. After this version, these steps are done automatically. |
| --- | --- |

Support has been added for database clustering by retrofitting and adding primary keys to all MES tables. This process is handled via system properties in the gateway configuration.

### Configuration
To enable the automatic primary key retrofit and addition, you must modify the **ignition.conf** file:

* In the **# Java Additional Parameters** section, add this property **wrapper.java.additional.N=-Dcom.sepasoft.db.addPrimaryKeys=true**
    * where N is the next available integer for the additional parameters.
* Restart the Ignition gateway to initiate the process.

### Monitoring and Verification

* **Logs:** The progress screen is no longer used; instead, everything is visible via the logs. You should check the logs for a correct progress report regarding the retrofit process.
* **Database:** Once the upgrade completes, verify that all tables have received the expected primary key column.

### Important Limitations and Best Practices

* **Oracle Database Incompatibility:** This property is unsupported on Oracle databases and enabling it will cause the system to crash.
* **System Performance:** Enabling this system property will slow down MES system startup, even after the database changes are complete.
* **Cleanup:** It is recommended to remove the system property from ignition.conf after the process completes to avoid startup delays.

### Advanced Configuration for Testing

For testing purposes—specifically regarding database initialization and upgrades—a secondary property is available:

* Property: -Dcom.sepasoft.db.disableAutoIdColumn=true
* Function: This forbids adding primary key columns during table creation.

**Testing Workflow:** To test the upgrade process, you can utilize the following workflow:

* Enable disableAutoIdColumn and comment out addPrimaryKeys in ignition.conf.
* Restart Ignition and recreate the database (tables will be created empty and without primary key columns).
* Enable addPrimaryKeys and restart Ignition again.
* Observe the logs to watch the tables being upgraded.