# Production Equipment Model \| Dual Live Analysis Folders from Enterprise Production Model rename

### Renaming Enterprise Name in Production Equipment Model

You rename your Enterprise name in the Production Model and find that the old and the new Folder(s) name
are now present in the MES Tag Provider

### Solution

valid for MES 3.0

to clear up the old legacy Live Analysis Folder we need to run this script in a GW Scope
for example as a Tag Change Script

```python
	f = system.mes.object.filter.createFilter()
	f.setMESObjectTypeName("Enterprise")
	ent_name = system.mes.loadMESObjects(f).get(0).getName()
	from java.lang import Class
	from com.inductiveautomation.ignition.common.tags.paths.parser import TagPathParser
	from com.inductiveautomation.ignition.common.browsing import BrowseFilter
	from com.inductiveautomation.ignition.gateway.tags.managed import ProviderConfiguration
	clazz = Class.forName('com.sepasoft.production.gateway.ProductionContext', False, f.class.getClassLoader())
	context = clazz.getDeclaredMethod('getInstance').invoke(None)
	tag_manager = context.getGatewayContext().getTagManager()
	provider = tag_manager.getOrCreateManagedProvider(ProviderConfiguration('MES'))
	for x in tag_manager.browseAsync(TagPathParser.parse('[MES]'), BrowseFilter()).get().getResults():
		if x.getName() != ent_name:
				provider.removeTag(x.getName())
```

This should run on the Gateway that has the extra Folder. (in Enterprise Settings, Tags are only on a Gateway and not synced.
It removes all top-level folders that do not have a name matching the current Enterprise