# MES Users \| Gateway User \(Sources\) to MES User in MES Object Editor 3\.0

### Sync Gateway and MES Users

The MES Object Editor does not "see" the users that are created in the Gateway User Sources Security menu

#### Solution 

MES Personnel objects are automatically created for any users added to any of the Ignition User Sources; However, the synchronization of users only occurs once every hour by default.

We can force a sync by calling the [system.mes.synchronizeMESPersonnel()](/smart/project-imported-manual/system-mes-synchronizemespersonnel) script function. The users will be synchronized from the same source as defined in the MES Settings for authentication.

Finally, keep in mind that the MES Object Editor, when looking for names, it literally means names

For example:

| Gateway<br><br>Security→Users→Manage Users | Gateway<br><br>Security→Users→Manage Users | MES Object Editor |
| --- | --- | --- |
| Username | Name | Personnel |
| dsmith | David Smith | ![](/resources/Storage/knowledge-base/gateway-user-sources-to-mes-user-in-mes-object-editor-3-0/image2018-8-24_7-56-50.png) |
| sdavidson | Sue Davidson | ![](/resources/Storage/knowledge-base/gateway-user-sources-to-mes-user-in-mes-object-editor-3-0/image2018-8-24_7-55-55.png) |

**Related Topics:**

* [MES Module Settings in Gateway](/smart/project-imported-manual/mes-module-settings-in-gateway)
* [Set Gateway as Root](/smart/project-imported-manual/set-gateway-as-root)