# Using a Custom Property for Equipment Path in MES Analysis 3\.0

## Overview

The **MES Analysis Selector** and **MES Analysis Controller** components both have a **Filter By** section that is typically set to the equipment path. Instead of settling for a static string value for the equipment path that must be changed manually (e.g. to run analysis on a different Line), you can create a Custom Property to use as a variable for the equipment path. This variable can now be modified on the fly via script or by binding it to the ***Equipment Item Path*** property of an **MES Object Selector**.

### Applies To and Version Info

This feature applies to the OEE 3.0 module.

 * * *

 ## Create a Custom Property

1. In either the **MES Analysis Selector** and **MES Analysis Controller** component, create a Custom Property to hold the equipment path string, such as "***eqPath***".
2. When used during run time, you can either modify the equipment path string held in this property via script or by binding it to the ***Equipment Item Path*** property of an **MES Object Selector**.

![](/resources/Storage/knowledge-base/using-a-custom-property-for-equipment-path-in-mes-analysis-3-0/image2022-12-16_16-53-0.png)

 * * *

 ## Bind Filter By to the Custom Property

### MES Analysis Selector: Set Filter By to the Custom Property

1. Edit the **Filter By**section:
    1. Set the "**=**" radio button in the **Operator** section.
    2. Select ***Equipment Path*** in the **Filter** section.
    3. Select your Custom Property (e.g. ***eqPath***) in the **Parameter** drop-down list.
    4. Click Add Expression. The expression will populate below.
    5. Click Save.

![](/resources/Storage/knowledge-base/using-a-custom-property-for-equipment-path-in-mes-analysis-3-0/image2022-12-16_16-54-38.png)

 ### MES Analysis Controller: Set Filter By with an Expression

The **Filter By** property of the **MES Analysis Controller** doesn't have a graphical 'wizard' like the **MES Analysis Selector** has, so you'll need to generate the full string yourself.

1. Create a String custom property (ex. eqPath) and bind to an MES Object Selector or other property on screen. Hard coding is an option during testing.
2. Type in the Ffilter By string. The string is simply:

Code

```
Equipment Path=eqPath
```


![](/resources/Storage/knowledge-base/using-a-custom-property-for-equipment-path-in-mes-analysis-3-0/image2022-12-16_17-0-19.png)

 * * *

 * * *
