Line Data Points

Sepasoft MES Module Suite

Line Data Points 

The Line Data points returns data for the line regardless of the Equipment the Live Analysis has been set up for.


Data PointData TypeDescriptionUnits

Equipment/Line/Downtime

Line Downtime Can Revert Split
BooleanTrue if the line downtime reason split can be reverted.N/A
Line Downtime End State Time Stamp
Date-TimeWhen down time events are rolled up, this is the time stamp of the last event.N/A
Line Downtime Equipment Name
StringName of the equipment that is responsible for causing line downtime.N/A
Line Downtime Equipment Path
StringProduction model equipment path for equipment that is responsible for causing line downtime.N/A
Line Downtime Event Sequence
Int4Every downtime event on the line is provided with an incrementing sequence number.N/A
Line Downtime Occurrence Count
Int4Number of downtime events for the selected period.N/A
Line Downtime Original Equipment Path
StringThe original path of the equipment that caused the line downtime before being reassigned to differed equipment.N/A
Line Downtime Original Reason
StringThe line or cell group (sub line) original downtime reason.N/A
Line Downtime Original Reason Code
Int4The line or cell group (sub line) original downtime reason code.N/A
Line Downtime Reason
String

The line or cell group (sub line) downtime reason.

Note
  • When the line is down the Line Downtime Reason is the same as the Line State Name.

  • When the line is up the Line Downtime Reason is blank.
N/A
Line Downtime Reason Path
StringThe reason name for line or cell group (sub line) downtime reasons, including Equipment State Class and any reasons above the selected reason in the state tree. E.g. Default Class/Unplanned Downtime/Mechanical Faults/Chain Slip.N/A
Line Downtime Reason Split
BooleanThe line downtime reason split indicator. True is current downtime event has been split into multiple downtime events.N/A
Line Downtime State Time Stamp
DateTimeThe time stamp for the equipment state change of the cell group (sub line) or cell that caused the line downtime events.N/A

Equipment/Line/Meantime

Line MTBF
Float8

The calculated Meantime (minutes) Between Failure for the line (or subline) in the selected period and does take into account the downtime detection method.

Refer to Configuring Equipment States > Meantime Metrics.

minutes
Line Meantime Metrics Enabled
BooleanReturns true if the current line (or subline) state is enabled for meantime metrics.N/A

Equipment/Line/Schedule

Line Schedule Available
BooleanDetermined by Ignition Shift schedule.  True if data returned is within a configured shift for the equipment.N/A
Line Schedule Available Time
Float8Time in minutes for available production time adjusted for line schedule availability and mode. "Line Schedule Available Time" is not applicable to cells or cell groups.minutes
Line Standard Count
String

Amount of product that should have been produced based on the line schedule available time and line standard rate. The available time is determined from the Ignition schedules that are selected for the line. If Ignition schedules are not selected for the line, then the scheduled count will be used. Actual line downtime is not used for this calculation.

See OEE Material Production Settings  > standard rate

N/A
Line Schedule Count
DoubleScheduled count of a machine.N/A
Line Schedule Duration
DoubleScheduled duration of a machine.minutes
Line Standard Count Variance
String

Variance between line standard count and line OEE outfeed count.


OEE Outfeed Count - Line Standard Count


N/A
Line Target Count
String

Amount of product that should have been produced based on the line schedule available time and line schedule rate. The available time is determined from the Ignition schedules that are selected for the line. If Ignition schedules are not selected for the line, then the scheduled count will be used. Actual line downtime is not used for this calculation.

See OEE Material Production Settings  > schedule rate

N/A
Line Target Count Variance
String

Variance between OEE Outfeed Count and Line Target Count.


OEE Outfeed Count - Line Target Count


N/A
Schedule Rate
Float8See OEE Material Production Settings  > schedule rateproduction units/unit of time
Scheduled Shift
StringScheduled shift, based on the assigned Ignition schedule.N/A
Scheduled Shift End Date Time
Date-TimeScheduled end date, based on the assigned Ignition schedule.N/A
Scheduled Shift Start Date Time
Date-TimeScheduled start date, based on the assigned Ignition schedule.N/A
Equipment/Line/Schedule/Entries
Calculated Scheduled Quantity
Float8The sum of all (request segment duration (minutes) * rate (converted to minutes)) for segments in a available time.production units
Entry Begin Date Time
Date-TimeThe begin time of the Operations Request.N/A
Entry End Date Time
Date-TimeThe end time of the Operations Request.N/A
Entry Request Segment End Date Time
Date-TimeThe End Time of Request Segments in the Operations Request.N/A
Entry Schedule Type
StringThe equipment operation schedule type, either "Held" or "Active".N/A
Entry Scheduled Duration
Float8The duration of a scheduled operation in minutes (only valid if the Entry Scheduled Method is set to "Duration"). Note: Value is 0 when Entry Scheduled Method is set to "Count".minutes
Entry Scheduled Method
StringThe equipment operation scheduling method, either "Count" or "Duration".N/A
Entry Scheduled Quantity
Int4The output count of a scheduled operation (only valid if the Entry Scheduled Method is set to "Count"). Note: Value is null when Entry Scheduled Method is set to "Duration".production units
Entry Scheduled Rate
Float8The "Rate" from the Material Property on the Segment. Note that units are either hours or minutes based on the Entry Schedule Rate Period setting.production units/unit of time (hours or minutes)
Entry Scheduled Rate Period
StringThe "Rate Period" property from the Material Property on the Segment, either "None", "Hour", "Min", or "Cycle".N/A
Operations Request Name
StringThe Name of the Operations Request object.N/A
Operations Request UUID
StringThe UUID of the Operations Request object.N/A

Equipment/Line/State

Line State Duration
Float8

The line or cell group (sub line) downtime event duration in minutes.

Important

Warning

Line state event duration will respect the group by for the analysis query. This means that the line state duration will be constrained to be within the time slice represented by the row, even if the line state event begin time is before the from time for the row or the line state event end time is after the to time for the row.

minutes
Line State Event Begin
Date-Time

The line or cell group (sub line) downtime event begin date time.


The Line State Event Begin Time and Line State Event End Time display the actual begin and end times, even if the times fall outside of the row to and from times.

N/A
Line State Event End
DateTime

The line or cell group (sub line) downtime event end date time.


The Line State Event Begin Time and Line State Event End Time display the actual begin and end times, even if the times fall outside of the row to and from times.

N/A
Line State Event Sequence
Int4The equipment state event sequence number.N/A
Line State Name
String

The line or cell group (sub line) state.

  • When the line is down the Line Downtime Reason is the same as the state name.

  • When the line is up the Line Downtime Reason is blank.

  • The Line State Name may differ from the Equipment State Name for the equipment item based on the Downtime Detection Mode.
    • E.g. Line State Tag indicates a state, but Key Reason (Cell Priority) Downtime Detection Mode overrides local Equipment State such that the Line State reflects the Key Cell State.
N/A
Line State Overridden
Boolean

When Key Reason Detection is set or Cell Groups are used, overriding the State must happen at the Line level.

N/A
Line State Override Scope
StringThe state override scope for a line or cell group (sub line). See Setting Up Equipment - Override Scope for more details.N/A
Line State Override Type
StringThe state override type for a line or cell group (sub line). See Setting Up Equipment - Override  for more details.N/A
Line State Type
StringThe line or cell group (sub line) state type. See Setting Up Equipment - State Type for more details.N/A
Line State Value
Int4The line or cell group (sub line) downtime state code. See Setting Up Equipment - State Code for more details.N/A

Sepasoft MES Module Suite