title: "Perspective Chart Dataset Properties"
id: "perspective-chart-dataset-properties"
project: "MES User Manual"
url: "https://docs.sepasoft.com/articles/user-manual/perspective-chart-dataset-properties"
updated: 2026-07-31T14:53:46Z
---

# Perspective Chart Dataset Properties

**Sepasoft MES Module Suite**

##  SPC Perspective Chart Dataset Properties 

These properties are available in the Ignition Properties Palette for SPC Charts.

![](/resources/Storage/user-manual/perspective-chart-dataset-properties/showAdditionalFactorColors.png)

| **Property Source** | 
```
propertySource
```
 | Sets the datasource mode. Toggle two options: **Use\_stored\_settings** | **Use\_binding**<br> <br>Included in Sepasoft Versions:<br> <br><br>| ![Warning](/resources/Storage/user-manual/user-manual/Warning.png) | MES 3.81.7 RC1 and later |<br>| --- | --- |<br> <br><br> <br>**Use\_stored\_settings:** Sets the chart to receive data from Stored Settings. **To use this, enter property values under storedSettings, see below**.<br> <br><br> <br>**Use\_binding:**Sets the chart to receive data from an SPC Controller. **To use this, bind to an SPC Controller under spcChartSettings, see below.**<br> <br><br><br>When clicking the binding icon on the left side of the propertySource, the Configure Property Binding dialog appears.<br><br>![](/resources/Storage/user-manual/perspective-chart-dataset-properties/perspective-chart-dataset-properties-2024-10-09-1.png) |
| --- | --- | --- |
| **Stored Settings** | storedSettings | Set property values here when **propertySource** is set to **Use\_stored\_settings** |
|  |  | | **Property Name** | **Data Type** | **Property Value Description** |<br>| --- | --- | --- |<br>| storedSPCName | String | **Required when propertySource = 'Use\_stored\_settings':** Sets name of the Stored SPC Setting. The name must match exactly to the name you enter in Stored SPC Selector.<br><br><br>| ![Note](/resources/Storage/user-manual/user-manual/Note.png) | Stored SPC Selector component only offered in VISION.<br><br>See [Stored SPC Selector | Vision](/articles/user-manual/stored-spc-selector-vision) |<br>| --- | --- | |<br>| location | String | **Optional:** Filter on a Location that is defined in Equipment Manager. Enter the Equipment Path to the Location. |<br>| startDate | Date | **Required:** Sets start date to filter SPC data on<br><br><br>| ![Note](/resources/Storage/user-manual/user-manual/Note.png) | Bind to form fields on the view to make dates selectable in runtime.![](/resources/Storage/user-manual/perspective-chart-dataset-properties/perspective-chart-dataset-properties-2024-10-09-2.png) |<br>| --- | --- |<br><br><br>**Required:** Sets end date to filter SPC filter on |<br>| endDate | Date |<br>| autoRefresh | Boolean | True/False **Required**: True, refreshes data when sample or definition information changes. **Set to True to use real-time data.** | |
| **SPC Chart Settings** |  | spcChartSettings <br>   ****  Set property values here when **propertySource** is set to **Use\_Binding**<br><br><br>**Bind to the SPC Controller** |
|  |  | | **Property Name** | **Data Type** | **Information** |<br>| --- | --- | --- |<br>| storedSPCName | String | Incoming property value from the SPC Controller &gt; Stored Setting. |<br>| startDate | Date | Sets start date to start filtering data on |<br>| endDate | Date | Sets end date to filter data on |<br>| autoUpdate | Boolean | Required True/False: True, updates data when a sample is taken. Use for realtime data. |<br>| autoRefresh | Boolean | Required True/False: True, refreshes data when sample or definition information changes. Use for realtime data. |<br><br> <br>![](/resources/Storage/user-manual/perspective-chart-dataset-properties/image%20%285%29.png) |
|  |  | **settings** <br> <br><br><br><br><br>| **additionalFactors**: | String - Additional factors to include in the SPC chart. |<br>| --- | --- |<br>| **attributeName:** | String - Name of the sample attribute |<br>| **attributeUnits**: | String - Adds a label for the unit of measure for the sample |<br>| **boxAndWhiskerFilter**<br><br>Chart Specific | String - Box and whisker filter items to filter on. |<br>| **controlLimits:** | String - Summarizes control limits to add to the chart |<br>| **definitionName:** | String - Name of the sample definition. |<br>| **filters:** | String -<br><br>**location:** The Location Path defined in the Equipment Manager to filter on.<br><br>**factors:** Properties &gt;Additional Factor<br><br>Filter on existing additional factors |<br>| **measurement:** | String - Measure number to filter on |<br>| **nonconformingFilter**<br><br>Chart Specific | String - Nonconforming items to filters on |<br>| **nonconformityFilter**<br><br>Chart Specific | String - Nonconformity items to filters on |<br>| **paretoFilter**<br><br>Chart Specific | String - Items to include in a Pareto chart. |<br>| **rowLimit:** | ****String - The maximum number of samples to return in the results. |<br>| **signals** | String - Summarizes your signal selections in a string. |<br>| **spcDataFormat:** | String - SPC Data<br><br><br>| ![Note](/resources/Storage/user-manual/user-manual/Note.png) | Each chart type has specific settings. Select the correct chart from the dropdown menu. |<br>| --- | --- | |<br>| **useDefaultChartTyp** **e:** | String - If true, uses the default chart type from the attribute definition. |<br>| **useDefaultChartTyp** **e:** | String - If true, uses the default chart type . |<br>| **enableFutureLimitEditing:** | String -If true, you can set limits for future (non-existing) samples. | |
|  |  | **histogram** <br> <br><br><br><br><br>| **autoBarCount**: | Boolean - If true, the number of data bars that are displayed is calculated automatically. |<br>| --- | --- |<br>| **dataBarCount** | int - The number of data bars to display when **autoBarCount** is False. |<br>| **paddingBarCount** | int - The number of bars prior to and following the data bars to include in the histogram results. | |
|  |  | **dynamic**<br><br>When using an SPC Controller to populate a Perspective SPC Chart, these dynamic filters can be used to filter the data for display in a chart.<br><br><br><br><br>| **factor** | String - Additional factors that were recorded along with the sample. |<br>| --- | --- |<br>| **location** | String - The location path where the samples were collected. |<br>| **productCode** | String - Samples returned should have this Product Code if present. |<br>| **referenceNo** | String - Samples returned should have this Reference Number if present. |<br>| **sampleApprovedBy** | String - The username of the user that approved the samples. |<br>| **sampleTakenBy** | String - The username of the user that recorded the samples. |<br>| **shift** | String - A schedule shift during which the samples were taken. | |
|  |  | **spcResults**<br><br>SPC Results including data, measurement count, messages and calculated value information.<br><br><br><br>**definitionUUI**<br><ul><li><strong>calcValueList</strong><ul><li><strong>defaultChart</strong></li><li><strong>measureFormat</strong></li><li><strong>unit</strong></li></ul></li></ul><br>**measurementCount**<br><ul><li><strong><strong>messages</strong></strong><ul><li><strong>errormessage</strong></li><li><strong>warningMessage</strong></li></ul></li></ul>**spcData: dataset - The SPC data.** |  |
| **showTable** | Boolean | Enable to display the data table. The table is updated as new data comes in. |  |
