##  Production Counters for OEE Metrics

OEE metrics use production counters. OEE calculations are done at the Line and Cell levels.

There are 4 types of counters:
 
* Infeed
* Outfeed
* Reject
* General

To get the best results for OEE calculation behavior:

* When there is only ***one*** type of MES Counter for the Line (either just an Infeed counter or just one or more Outfeed counters), it/they must be created on the Line in the Production Model.

***Note that having only one counter, created on a Cell in the Production Model, does not allow the Line OEE calculations to be calculated correctly.***

* When there are ***both*** an **Infeed counter** and an **Outfeed counter** (both on the Line, both on Cells, or a mix), make sure that the Infeed Count Equipment and Outfeed Count Equipment in the Material Definition  ***both*** point to the locations where the MES Counters were created in the Production Model.

###  Serial Cells

In these scenarios, each cell in the production line flows into the next cell, in series (there are no branches to the production line).

The diagram to the right shows all of the possible ***physical*** placements for photoeye detectors used to count the infeed, outfeed and reject parts in the examples below. The diagrams in the table below show where the MES Counters were created (which equipment).

The table below has some examples of various production line configurations, along with the OEE behavior that results based on how MES Counters are created in the Production Model and how the Material Definition counter selections are made.
 
![](/resources/Storage/user-manual/production-counter-assignments/Production%20Line%20-%20Series_1x.png)

* * *

| **#** | **Scenario** | **Production Model** | **Material Definition** | **OEE Behavior**<br> <br>**OEE Quality = (OEE Infeed - OEE Reject) / OEE Infeed** |
| MES Counter Location | MES Counter Location | MES Counter Location | Infeed Count Equip. | Outfeed Count Equip. |
| :---: | :---: | :---: | :---: | :---: |
| **1** | ![](/resources/Storage/user-manual/production-counter-assignments/Infeed-Line_1x.png) | Line 1 | n/a | n/a | Line 1 | Line 1 | **[VALID]**<br><ul> <li> <span style="font-size: 13.0pt;letter-spacing: 0.0px;">OEE Outfeed = OEE Infeed</span> </li> <li> <span style="font-size: 13.0pt;letter-spacing: 0.0px;">Reject = 0</span> </li> <li> <span style="font-size: 13.0pt;letter-spacing: 0.0px;">Quality = 100%</span> </li> </ul> |
| **2** | ![](/resources/Storage/user-manual/production-counter-assignments/Outfeed-Line_1x.png) | n/a | Line 1 | n/a | Line 1 | Line 1 | **[VALID]**<br><ul> <li> <span>OEE Infeed = OEE Outfeed</span> </li> <li> <span>Reject = 0</span> </li> <li> <span>Quality = 100%</span> </li> </ul> |
| **3** | ![](/resources/Storage/user-manual/production-counter-assignments/Infeed-Line%20Rejects-Cells_1x.png) | Line 1 | n/a | Cell 1 <br>and <br>Cell 2 | Line 1 | Line 1 | **[VALID]**<br><ul> <li> <span>OEE Outfeed = OEE Infeed - sum of rejects</span> </li> <li> <span>Reject = sum of rejects on cells</span> </li> <li> <span>Quality = calculated</span> </li> </ul> |
| **4** | ![](/resources/Storage/user-manual/production-counter-assignments/Outfeed-Line%20Rejects-Cells_1x.png) | n/a | Line 1 | Cell 1 <br>and <br>Cell 2 | Line 1 | Line 1 | **[VALID]**<br><ul> <li> <span>OEE Infeed = OEE Outfeed -&#160;sum of rejects</span> </li> <li> <span>Reject = sum of rejects on cells</span> </li> <li> <span>Quality = calculated</span> </li> </ul> |
| **5** | ![](/resources/Storage/user-manual/production-counter-assignments/image2021-8-31_8-57-34.png) | Cell 1 | n/a | Cell 1 and Cell 2 | Cell 1 | Line 1 | **[VALID]**<br><ul title=""> <li> <span>OEE Outfeed = OEE Infeed - sum of rejects</span> </li> <li> <span>Reject = sum of rejects on cells</span> </li> <li> <span>Quality = calculated</span> </li> </ul> <br>Included in Sepasoft Versions:<br> <br><br>| ![Warning](/resources/Storage/user-manual/user-manual/Warning.png) | MES 2.81.0 SP12 and later <br>MES 2.79.0 SP12 and later<br> <br>MES 3.81.1 SP7 and later <br>MES 3.79.0 SP7 and later |<br>| --- | --- | |
| **6** | ![](/resources/Storage/user-manual/production-counter-assignments/image2021-8-31_9-7-56.png) | n/a | Cell 3 | Cell 1 and Cell 2 | Line 1 | Cell 3 | **[VALID]**<br><ul title=""> <li> <span>OEE Infeed = OEE Outfeed - sum of rejects</span> </li> <li> <span>Reject = sum of rejects on cells</span> </li> <li> <span>Quality = calculated</span> </li> </ul> <br>Included in Sepasoft Versions:<br> <br><br>| ![Warning](/resources/Storage/user-manual/user-manual/Warning.png) | MES 2.81.0 SP12 and later <br>MES 2.79.0 SP12 and later<br> <br>MES 3.81.1 SP7 and later <br>MES 3.79.0 SP7 and later |<br>| --- | --- | |
| **7** | ![](/resources/Storage/user-manual/production-counter-assignments/Infeed-Outfeed-Cells_1x.png) | Cell 1 | Cell 3 | n/a | Cell 1 | Cell 3 | **[VALID]**<br><ul> <li> <span style="font-size: 13.0pt;letter-spacing: 0.0px;">Reject = Infeed - Outfeed <br> <em>(taking into account scaling and package count)</em></span> </li> <li> <span>Quality = incorrect</span> </li> </ul> |
| **8** | ![](/resources/Storage/user-manual/production-counter-assignments/Infeed-Outfeed-Cells%20Rejects-Cells_1x.png) | Cell 1 | Cell 3 | Cell 1 <br>and <br>Cell 2 | Cell 1 | Cell 3 | **[VALID]**<br> <br>Ideal configuration:<br><ul> <li> <span style="font-size: 13.0pt;letter-spacing: 0.0px;">Provides full capability of counting Infeed, Outfeed and Rejects</span> </li> <li> <span style="font-size: 13.0pt;letter-spacing: 0.0px;">Calculates Performance and Quality correctly</span> </li> </ul> |
| **9** | ![](/resources/Storage/user-manual/production-counter-assignments/Outfeed-Line%20Rejects-Line_1x.png) | n/a | Line 1 | Line 1 | Line 1 | Line 1 | **[VALID]**<br><ul title=""> <li>OEE Infeed = Outfeed -&#160;<span>sum of rejects</span><span> <br> <em>(taking into account scaling and package count) <br>(better accuracy than scenarios 3 and 4 above)</em></span> </li> </ul> |

###  Parallel Cells

 In the scenarios below, the production line utilizes divergent (parallel) packaging cell options.
 
In this example, items manufactured in previous cells can be diverted into one of two packaging cells, Case or Tray, for shipping products either by the case or by the tray, based on the demand for each in the market.
 
The diagram to the right shows all of the possible ***physical*** placements for photoeye detectors used to count the infeed, outfeed and reject parts in the examples below. The diagrams in the table below show where the MES Counters were created (which equipment).
 
The table below has some examples of various production line configurations, along with the OEE behavior that will result based on how MES Counters are created in the Production Model and how the Material Definition counter selections are made.

![](/resources/Storage/user-manual/production-counter-assignments/Production%20Line%20-%20Parallel_1x.png)
 | **#** | **Scenario** | **Production Model** | **Material**  **Definition** | **OEE Behavior** |
| MES Counter Location | MES Counter Location | MES Counter Location | Infeed Count Equip. | Outfeed Count Equip. |
| :---: | :---: | :---: | :---: | :---: |
| **10** | ![](/resources/Storage/user-manual/production-counter-assignments/Outfeeds-Line_1x.png) | n/a | Line 1 <br>(both packers) | n/a | Line 1 | Line 1 | **[VALID]**<br><ul> <li> <span>OEE Outfeed = OEE Infeed</span> </li> <li> <span>Reject = 0</span> </li> <li> <span>Quality = 100%</span> </li> </ul> <br>*Note: Runs using the Case Packer will drive Case Packer Outfeed counter up. Runs using Tray Packer will push Tray Packer Outfeed counter up.* |
| **11** | ![](/resources/Storage/user-manual/production-counter-assignments/Outfeeds-Cells_1x.png) | n/a | Cell 3 <br>and <br>Cell 4 | n/a | Line 1 | Cell 3**\*** <br> or <br>Cell 4**\*** | **[NOT VALID]**<br><ul> <li> <span>OEE Infeed = 0</span> </li> <li> <span style="font-size: 13.0pt;letter-spacing: 0.0px;">Quality = incorrect</span> </li> <li> <span>Performance = incorrect</span> </li> </ul> <br>*Note: Place both of the Outfeed counters on Line 1 instead.* |
| **12** | ![](/resources/Storage/user-manual/production-counter-assignments/Infeed-Cell%20Outfeeds-Cells_1x.png) | Cell 1 | Cell 3 <br>and <br>Cell 4 | n/a | Cell 1 | Cell 3**\*** <br> or <br>Cell 4**\*** | **[VALID]**<br><ul> <li> <span>Reject = Outfeed - Infeed <br> <em>(taking into account scaling and package count)</em></span> </li> </ul> |
| **13** | ![](/resources/Storage/user-manual/production-counter-assignments/Infeed-Line%20Outfeeds-Cells_1x.png) | Line 1 | Cell 3 <br>and <br>Cell 4 | n/a | Line 1 | Cell 3**\*** <br> or <br>Cell 4**\*** | **[VALID]**<br><ul> <li> <span>Reject = Outfeed - Infeed <br> <em>(taking into account scaling and package count)</em></span> </li> </ul> |

**\*** Either Cell 3 or Cell 4, depending on the Material being manufactured.
 