title: "SPC Pareto Chart - Perspective"
id: "spc-pareto-chart-perspective"
project: "MES User Manual"
url: "https://docs.sepasoft.com/articles/user-manual/spc-pareto-chart-perspective"
updated: 2026-07-31T14:58:16Z
---

# SPC Pareto Chart \- Perspective

**Sepasoft MES Module Suite**
 A Pareto Chart is a graph that indicates the frequency of defects, as well as their cumulative impact. Pareto Charts are useful to find the defects to prioritize in order to observe the greatest overall improvement.

![](/resources/Storage/user-manual/spc-pareto-chart-perspective/image2023-6-23_10-11-6.png)

Included in Sepasoft Versions:

| ![Warning](/resources/Storage/user-manual/user-manual/Warning.png) | MES 3.81.7 RC1 and later |
| --- | --- |

![](/resources/Storage/user-manual/spc-pareto-chart-perspective/image2022-11-9_5-18-24.png)

**Ignition DesignerPerspective Component Palette**
 * * *

##  SPC Perspective Chart Dataset Properties 

These properties are available in the Ignition Properties Palette for SPC Charts.

![](/resources/Storage/user-manual/perspective-chart-dataset-properties/showAdditionalFactorColors.png)

| **Property Source** | 
```
propertySource
```
 | Sets the datasource mode. Toggle two options: **Use\_stored\_settings** | **Use\_binding**<br> <br>Included in Sepasoft Versions:<br> <br><br>| ![Warning](/resources/Storage/user-manual/user-manual/Warning.png) | MES 3.81.7 RC1 and later |<br>| --- | --- |<br> <br><br> <br>**Use\_stored\_settings:** Sets the chart to receive data from Stored Settings. **To use this, enter property values under storedSettings, see below**.<br> <br><br> <br>**Use\_binding:**Sets the chart to receive data from an SPC Controller. **To use this, bind to an SPC Controller under spcChartSettings, see below.**<br> <br><br><br>When clicking the binding icon on the left side of the propertySource, the Configure Property Binding dialog appears.<br><br>![](/resources/Storage/user-manual/perspective-chart-dataset-properties/perspective-chart-dataset-properties-2024-10-09-1.png) |
| --- | --- | --- |
| **Stored Settings** | storedSettings | Set property values here when **propertySource** is set to **Use\_stored\_settings** |
|  |  | | **Property Name** | **Data Type** | **Property Value Description** |<br>| --- | --- | --- |<br>| storedSPCName | String | **Required when propertySource = 'Use\_stored\_settings':** Sets name of the Stored SPC Setting. The name must match exactly to the name you enter in Stored SPC Selector.<br><br><br>| ![Note](/resources/Storage/user-manual/user-manual/Note.png) | Stored SPC Selector component only offered in VISION.<br><br>See [Stored SPC Selector | Vision](/articles/user-manual/stored-spc-selector-vision) |<br>| --- | --- | |<br>| location | String | **Optional:** Filter on a Location that is defined in Equipment Manager. Enter the Equipment Path to the Location. |<br>| startDate | Date | **Required:** Sets start date to filter SPC data on<br><br><br>| ![Note](/resources/Storage/user-manual/user-manual/Note.png) | Bind to form fields on the view to make dates selectable in runtime.![](/resources/Storage/user-manual/perspective-chart-dataset-properties/perspective-chart-dataset-properties-2024-10-09-2.png) |<br>| --- | --- |<br><br><br>**Required:** Sets end date to filter SPC filter on |<br>| endDate | Date |<br>| autoRefresh | Boolean | True/False **Required**: True, refreshes data when sample or definition information changes. **Set to True to use real-time data.** | |
| **SPC Chart Settings** |  | spcChartSettings <br>   ****  Set property values here when **propertySource** is set to **Use\_Binding**<br><br><br>**Bind to the SPC Controller** |
|  |  | | **Property Name** | **Data Type** | **Information** |<br>| --- | --- | --- |<br>| storedSPCName | String | Incoming property value from the SPC Controller &gt; Stored Setting. |<br>| startDate | Date | Sets start date to start filtering data on |<br>| endDate | Date | Sets end date to filter data on |<br>| autoUpdate | Boolean | Required True/False: True, updates data when a sample is taken. Use for realtime data. |<br>| autoRefresh | Boolean | Required True/False: True, refreshes data when sample or definition information changes. Use for realtime data. |<br><br> <br>![](/resources/Storage/user-manual/perspective-chart-dataset-properties/image%20%285%29.png) |
|  |  | **settings** <br> <br><br><br><br><br>| **additionalFactors**: | String - Additional factors to include in the SPC chart. |<br>| --- | --- |<br>| **attributeName:** | String - Name of the sample attribute |<br>| **attributeUnits**: | String - Adds a label for the unit of measure for the sample |<br>| **boxAndWhiskerFilter**<br><br>Chart Specific | String - Box and whisker filter items to filter on. |<br>| **controlLimits:** | String - Summarizes control limits to add to the chart |<br>| **definitionName:** | String - Name of the sample definition. |<br>| **filters:** | String -<br><br>**location:** The Location Path defined in the Equipment Manager to filter on.<br><br>**factors:** Properties &gt;Additional Factor<br><br>Filter on existing additional factors |<br>| **measurement:** | String - Measure number to filter on |<br>| **nonconformingFilter**<br><br>Chart Specific | String - Nonconforming items to filters on |<br>| **nonconformityFilter**<br><br>Chart Specific | String - Nonconformity items to filters on |<br>| **paretoFilter**<br><br>Chart Specific | String - Items to include in a Pareto chart. |<br>| **rowLimit:** | ****String - The maximum number of samples to return in the results. |<br>| **signals** | String - Summarizes your signal selections in a string. |<br>| **spcDataFormat:** | String - SPC Data<br><br><br>| ![Note](/resources/Storage/user-manual/user-manual/Note.png) | Each chart type has specific settings. Select the correct chart from the dropdown menu. |<br>| --- | --- | |<br>| **useDefaultChartTyp** **e:** | String - If true, uses the default chart type from the attribute definition. |<br>| **useDefaultChartTyp** **e:** | String - If true, uses the default chart type . |<br>| **enableFutureLimitEditing:** | String -If true, you can set limits for future (non-existing) samples. | |
|  |  | **histogram** <br> <br><br><br><br><br>| **autoBarCount**: | Boolean - If true, the number of data bars that are displayed is calculated automatically. |<br>| --- | --- |<br>| **dataBarCount** | int - The number of data bars to display when **autoBarCount** is False. |<br>| **paddingBarCount** | int - The number of bars prior to and following the data bars to include in the histogram results. | |
|  |  | **dynamic**<br><br>When using an SPC Controller to populate a Perspective SPC Chart, these dynamic filters can be used to filter the data for display in a chart.<br><br><br><br><br>| **factor** | String - Additional factors that were recorded along with the sample. |<br>| --- | --- |<br>| **location** | String - The location path where the samples were collected. |<br>| **productCode** | String - Samples returned should have this Product Code if present. |<br>| **referenceNo** | String - Samples returned should have this Reference Number if present. |<br>| **sampleApprovedBy** | String - The username of the user that approved the samples. |<br>| **sampleTakenBy** | String - The username of the user that recorded the samples. |<br>| **shift** | String - A schedule shift during which the samples were taken. | |
|  |  | **spcResults**<br><br>SPC Results including data, measurement count, messages and calculated value information.<br><br><br><br>**definitionUUI**<br><ul><li><strong>calcValueList</strong><ul><li><strong>defaultChart</strong></li><li><strong>measureFormat</strong></li><li><strong>unit</strong></li></ul></li></ul><br>**measurementCount**<br><ul><li><strong><strong>messages</strong></strong><ul><li><strong>errormessage</strong></li><li><strong>warningMessage</strong></li></ul></li></ul>**spcData: dataset - The SPC data.** |  |
| **showTable** | Boolean | Enable to display the data table. The table is updated as new data comes in. |  |

**Pareto Chart Specific Properties**

|  | Scripting Reference |  |  |  |  |
| --- | --- | --- | --- | --- | --- |
|  | **xAxisVerticalTickLabels** | Boolean | Enables labels on the vertical tick marks on the x-axis. |
|  | **vertical** | Boolean | Sets the orientation of the chart. When set to True, the chart displays with vertical bars. |
|  | **categoryAxisTitle** | String | Adds a title to the category axis. |
|  | **frequencyAxisTitle** | String | Adds a title to the frequency axis. |
|  | **percentAxisTitle** | String | Adds a title to the percentage axis. |
|  | **showAccumulationLine** | Boolean |  |
|  | **showWeightedValues** | Boolean | When set to True, the count values are adjusted by the weight value in [Sample Definition](/articles/user-manual/Sample-Definitions) &gt; [Attribute settings](/articles/user-manual/Sample-Definition-Attributes).<br><br>![](/resources/Storage/user-manual/spc-pareto-chart-perspective/image2022-11-28_8-43-11.png) |
|  | **maxBarCount** | Integer | Limits the number of bars on the chart. |
|  | **weightAxisTitle** | String | Title to show when displaying weighted values for the frequency axis. |
|  | **axisStyle** |  |  |
|  |  | **axisTitleColor** | Color picker | Color for both axis titles. |
|  |  | **axisTitleFont** | String | Font family for both axis titles |
|  | **chartStyle** | **chartBackground** | String | Color of the background of the chart. |
|  |  | **horzGridLineColor** | Color, picker available | Color of the horizontal grid line. |
|  |  | **showHorizontalGridLines** | Boolean | If true, show horizontal grid lines on charts. |
|  | **chartDataStyle** |  |  |
|  |  | **accumulationLineColor** | Color picker | Color for accumulation. |
|  |  | **barColor** | Color picker | Color for bars. |
|  |  | **barSpacing** | Integer | Spacing between bars as a percentage of the bar width. |
|  |  | **gradient** | Boolean | When True, painted with a gradient shine |
|  |  | **shadow** | Boolean | When True, painted with drop shadow. |
|  | **tickStyle** |  |  |
|  |  | **tickLabelColor** | Color picker | Sets the color for the tick style. |
|  |  | **tickLabelFont** | String | Sets the font family for the tick labels. |
|  | **noDataStyle** |  |  |
|  |  | **noDataForeground** | Color picker |
|  |  | **noDataFont** | Sets the font family for the no data message |

****

### Meta Properties in the Perspective Property Editor

| Name<br><br>Scripting Reference | Data Type | Description | Description | Description |
| --- | --- | --- | --- | --- |
| **name** | String | Name of the component. Used in scripting and component tree paths by name, such as during Property Binding. |
| **visible** | Boolean | Whether or not this component should display. |
| **tooltip** |  |  |
| **enable** | Boolean | Whether the tooltip on hover |
| **width** | Integer | The height of the table rows. |
| **text** | String | The scroll bar x position. |
| **style** | Boolean | Toggle to show or hide the sample data table. |
| **delay** | Boolean | Image icon to show to edit control limits. |
| **sustain** | Integer | Time, in milliseconds, to display tooltip before removing it. A value of 0 results in the tooltip displaying until the mouse exits the components. |
| **location** | Boolean | The location where the tooltip displays. |
| **tail** | Boolean | Enables a decorative triangle on the tooltip that points to the tooltip owner. Ignored when location uses a value of 'mouse'. |

 ****
 Event Handlers

Event handlers provide the ability to add custom script when a user interacts with a component.

* .beforeUpdate() ![](/resources/Storage/user-manual/check.png)
* .afterUpdate() ![](/resources/Storage/user-manual/check.png)

Refer to the [Ignition User Manual](https://docs.inductiveautomation.com/display/DOC80/Welcome) for details on using the available event handlers:

* [Ignition: Component Events and Actions](https://docs.inductiveautomation.com/display/DOC80/Component-Events-and-Actions)
* [Ignition: Perspective Event Types Reference](https://docs.inductiveautomation.com/display/DOC80/Perspective-Event-Types-Reference)

## Extension Functions

Functions implemented

* .update() ![](/resources/Storage/user-manual/check.png)
* .refreshInfo() ![](/resources/Storage/user-manual/check.png)

## Component Functions

Example of the component on the page root container:

**event.source.parent.getComponent('Box and Whisker Chart').showSetLimitPanel** **(True)**.

showSetLimitPanel
* Description

Causes the calculate and set control limit dialog to be shown.

* Parameters

Boolean - True/False

* Return

Nothing

* Scope

Client

**Sepasoft MES Module Suite**