title: "system.mes.oee.splitEquipmentStateValue"
id: "system-mes-oee-splitequipmentstatevalue"
project: "MES User Manual"
url: "https://docs.sepasoft.com/articles/user-manual/system-mes-oee-splitequipmentstatevalue"
updated: 2026-07-31T14:54:43Z
---

# system\.mes\.oee\.splitEquipmentStateValue

**Sepasoft MES Module Suite**
 
Description

Split a single downtime event into two downtime events.

This is useful if there are two causes for a downtime event and different reasons can be assigned to each separately.

This script function can be called multiple times to split the downtime event into 3 or more separate events.

| ![Warning](/resources/Storage/user-manual/user-manual/Warning.png) | If a downtime event that has a note is split, the note will only stay on the original downtime reason and not be copied over (duplicated) to the new split state. |
| --- | --- |

| ![Warning](/resources/Storage/user-manual/user-manual/Warning.png) | Once a downtime event is split, only the original event may be split again. The newly-split portion cannot be split (but a Downtime Reason note can be added). |
| --- | --- |

Syntax

**system.mes.oee.splitEquipmentStateValue(baseEquipmentPath, reasonEquipmentPath, stateTimeStamp, eventTimeStamp, splitTimeStamp)**

* Parameters

[String](/articles/user-manual/Data-Types-and-Formats) baseEquipmentPath - The equipment path for the line or if managing downtime events for a cell group, the equipment path for the cell group.

[String](/articles/user-manual/Data-Types-and-Formats) reasonEquipmentPath - The equipment path for the original equipment that caused the downtime event.

[Date](/articles/user-manual/Data-Types-and-Formats) stateTimeStamp- The timestamp of the state that is at the source of the downtime event.

| ![Error](/resources/Storage/user-manual/Error.png) | The state timestamp is not always the same as the downtime event timestamp and using the downtime event timestamp will not always produce consistent results. |
| --- | --- |

[Date](/articles/user-manual/Data-Types-and-Formats) eventTimeStamp- The timestamp of the line or cell group downtime event. Note that is not always the same as the timestamp of the state that cause the downtime event.

[Date](/articles/user-manual/Data-Types-and-Formats) splitTimeStamp- The timestamp of where to split the downtime event. It must be between the start and end of the line or cell group downtime event.

* Returns

Nothing

* Scope

All
 
Code Examples

Code Snippet

Code

```
# Splitting the downtime event on the filler 5 seconds after the state was recorded


base_equipment_path = 'Enterprise\Site\Area\Line 2'
reason_equipment_path = 'Enterprise\Site\Area\Line 2\Filler'
split_time_stamp = system.date.addSeconds(state_time_stamp, 5)


system.mes.oee.splitEquipmentStateValue(base_equipment_path, reason_equipment_path, state_time_stamp, event_time_stamp, split_time_stamp)  
```
  
**Sepasoft MES Module Suite**