Batch Command Signature Component

Sepasoft MES Module Suite

Batch Command Signature Component Properties

Properties are provided that can be set to affect the operation and look of the component. They can be set through the Perspective Property Editor in the Designer or through scripting. Note that the section prefix is included before the property name (props, position, custom, or meta).

Example

JSON
self.getSibling("BatchCommandSignature").props.batchId = selectedBatchId

Name

Scripting

Property Type

Description

Batch ID

batchId

String

Batch Queue Entry ID targeted by all command actions from this component. The component controls one Batch Queue Entry at a time. Leave blank until a batch is selected; command buttons remain disabled until a Batch ID is set.

User

user

String

Name of the user recorded in the EBR for commands that do not require a signature. When a signature requirement is fulfilled, the approving signer(s) are recorded instead (comma-separated for multi-signer approvals). If blank and no signature applies, the Perspective session user is used when available.

Signature Templates

signatureTemplates

Object

Per-command Signature Template names (plain strings). See Signature Templates below. A blank string means unset and falls through to the built-in/global template for that command, or to no signature.

Enable Play

enablePlay

Boolean

Controls whether the contextual Start / Play command is allowed from this component. Defaults to true. The command is still subject to Batch state enablement and a configured Batch ID.

Enable Pause

enablePause

Boolean

Controls whether the Pause command is allowed. Defaults to true.

Enable Hold

enableHold

Boolean

Controls whether the Hold command is allowed. Defaults to true.

Enable Stop

enableStop

Boolean

Controls whether the Stop command is allowed. Defaults to true.

Enable Reset

enableReset

Boolean

Controls whether the Reset command is allowed. Defaults to true.

Enable Abort

enableAbort

Boolean

Controls whether the Abort command is allowed. Defaults to true.

Style

style

Style Object

Perspective style applied to the command toolbar. Refer to the Ignition Style Reference for classes, colors, fonts, and related settings.